Most buildings will be equipped with air-conditioning or air-conditioning systems. For companies renting office space, it is difficult to provide a complete computer room. I believe that many computer room maintenance personnel will encounter such a situation: when the rented office building does not allow independent outdoor units, and the central air conditioner is turned off at night, how should the computer room dissipate heat?
In the face of similar problems, experts have given some effective methods, all of which are real knowledge in practice, to see which method is more appropriate to your situation.
1. Moving away is the best solution.
2. If the computer room is not large, you can choose floor-mounted mobile air-conditioning.
3, the server room server is about 10, the area is less than 1.5 square meters. After work, you can choose to shut down or hibernate unwanted servers. There are only DC, Mail, Web and NAS (HDD sleep) left in the holiday, and all others are turned off. It is exhausted for 15 minutes every 3 hours at night and discharged to a light steel frame.
4. Practice shows that an indoor air conditioner is installed (the main unit is still indoors), and the heat dissipation effect is not very good. The budget is sufficient to choose water-cooled.
5, indoor hanging and hanging a water-cooled air-conditioner, fixed on the ceiling and not in the machine room, and then the hole in the building's cold water pipe (usually near the toilet room), Connect the thin tube to the air conditioner.
The specific method is: please ask the manufacturer to install the water pressure induction start switch, and you need to apply to the building management center before the construction can be carried out. Once the central air conditioning system of the building stops the main water tower and activates the standby water tower on holidays, It will switch to the indoor suspended water-cooled air conditioner to supply air cooling to the engine room. When the normal working, the standby water tower will stop running, and the central air conditioning system switched to the main water tower will supply cold air to the engine room.
It is necessary to consider in advance that the building management center will charge an additional management fee to your company every month, which will depend on the number of tons of your air-conditioner.
The manufacturer will help you pull the ventilation line, but you should follow the direction of the server's exhaust, consider the location of the cold air and the hot air discharge (the vent hole of the light steel frame should be above the machine room). Let the heat in the machine room be smoothly discharged into the light steel frame compartment above the large office.
As organizations grow, the number of internal application systems is increasing, and the performance
Selecting protection for a virtual infrastructure is like buying an anti-virus software product for
As Web servers are being targeted by more and more hackers and worm m
IIS (Internet Information Server) is a Web service component provided by Windows.
IIS troubleshooting guide and error code full
Management Server: Common Six Reasons for Servers to Crash
Break the limit and let the IIS server run on demand
The management server ensures that the actual management experience of security is shared.
Nginx reports "readv() failed (104: Connection reset by peer)"
Briefly use linux to build www server (3)
Explain how IIS web server handles ASP.NET requests (Figure)
Putty network error: Connection refused garbled
Under the CMD read the port code of the server terminal code
Linux server cluster system implementation solution detailed analysis
How to open and cancel the defragmentation task of Win7 for personalization
How to restore the original notebook
For Win10 (Mobile), Microsoft shows high-profile love to Apple and iOS developers
Teach you to identify the expansion of the U disk
How to set up win8 fast key shutdown
Win8 boot start can not complete the update What is the change?
How does Win10 set up headphones and audio at the same time?
How to use ftp command under Linux
How does Win10 directly delete files without going through the recycle bin
Win10 standby wake-up standby after the wifi connection is not resolved