Teach you three tricks, and the electrical fire in the computer room said no!

  

A recent survey shows that cabinet power has become a bottleneck in the electrical safety of the equipment room. It often has load capacity exceeding the connection line and circuit structure, causing accidents such as heat accumulation, fire, open circuit, data loss, and even electrical fires. occur. Breaking through the latest professional PDU products from Electric, the whole series has 27 models, which has raised the stability and safety of cabinet power supply to a new level. The three core technologies make the machine room and electrical fire Say No!

- Lightning Eliminator (SPD), always protect equipment safety

Surge is a transient over-voltage or over-current phenomenon in the circuit, usually only occurs in a few microseconds, but due to the high energy, It often causes serious damage to precision circuits.

Breakthrough SPD lightning eliminator, built-in exclusive development of "smart core M & G surge protection technology", anti-instantaneous high current capability up to 10000 amps, start-up time <1 microsecond, to achieve indoor lightning protection The highest level, but also a variety of daily power surges in the daily protection circuit.

The second measure - air switch, high-power overload protection

The equipment used in the equipment room, the power is much larger than the household, the ordinary household overload protector can not reach the industrial current-carrying index, once An instantaneous high voltage occurs, and expensive equipment is destroyed by current in an instant. In response to this problem, the breakthrough PDU products are equipped with high-power overload protectors or air switches, which can meet the needs of 16A and 32A. When the circuit is short-circuited, overloaded or the voltage is seriously reduced, the power can be automatically cut off to protect the back-end electrical appliances.

The third measure - effective temperature rise control, cabinet operation is more secure

Breakthrough project expansion PDU, through three technical treatments, the PDU temperature rise indicator can be effectively controlled:

The first is the copper material for the metal parts in the PDU. Breakthrough engineering expansion PDU uses tin (phosphorus) bronze with excellent conduction performance, containing more than 90% copper, and the price is 4-5 times that of ordinary copper.

The second is the internal wire connection method. The breakthrough PDU adopts a one-piece copper plate stamping process, and the wires are connected without solder joints, so as to make the conductive process as smooth as possible, and reduce the possibility of high temperature open welding.

The third is the space design inside the PDU. Many PDUs on the market are exquisite in design, but the actual internal space is unreasonable, which is not conducive to the heat dissipation, and it is easy to cause heat accumulation, causing high temperature rise and increasing the possibility of danger. The breakthrough project expansion PDU adopts ultra-low temperature space design, and there is enough heat dissipation space inside, which can effectively avoid the electrical fire hazard caused by the excessive accumulation of heat due to the long-term work of the PDU.