Solving the problem that Vista can't use input method normally

  

Many friends in Windows Vista complain that the input method cannot be used normally. For example, the five-stroke input cannot be used normally, the purple pinyin cannot be used, and the pinyin plus can not be used. Especially when running in IE browser.

This time is generally due to the role of the IE protection mode, because the IE protection mode depends on the role of UAC, UIPI and MIC, so it can be considered that the security function of UAC, UIPI or MIC causes problems with these input methods. .

1、一山不容二虎

The IE process in protected mode runs at the “low” level, so it cannot be written to the user profile area, thus preventing malicious web pages from damaging users and systems. data. At the same time, IE will automatically redirect this write operation to a specific area. This ensures security while keeping IE components and add-ons up and running.

But if the IE add-in must share data with a "medium" process, then there may be problems, because the data accessed by the IE process (add-in) is actually heavily Oriented, and "intermediate" will still go to the original location, which may lead to errors.

Solution: Modify these add-ons so that they have access to a specific zone at the same time as the external process; or let the external process run at the "low level" level.

Alternatively, you can manually modify the system to set the shared area to allow access to the "low level" process.

2, UIPI troubles

If the IE add-in needs to send Windows messages to external processes, it will be blocked. This is due to the role of UIPI, which only allows advanced processes to send messages to peer or low-level processes. This is somewhat similar to previous underground parties, allowing only superiors to contact subordinates (single line contact). But this may affect some old input methods and cause them to not work properly.

Solution: Modify the input method to allow external processes to accept specified Windows messages. Or use a security mechanism such as RPC to communicate between the IE process and the advanced process.

At present, you can only manually modify the system, forcibly disable UIPI, and ensure the compatibility of the input method. However, this will weaken the security of the system, and it will also castrate the function of the IE protection mode (although the system prompts that the IE protection mode is still working, it has been greatly weakened).

In HKEY_LOCAL_MACHINE\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Policies\\System, create a new DWORD key value EnableUIPI, set to 0.

Restart the system, and then test a few times, it should be able to solve the problem of similar purple pinyin, pinyin plus, and is really "completely".